Hospitals have a more demanding power supply. The power for hospitals allows absolutely no interruption and must be provided in a super silent way. to meet the demanding requirements, the power generators must have excellent performance, also AMF and ATS are required.
Requirements and Challenges
1.Working conditions
24 hours consecutive stable power output at rated power
(10% overload for 1 hour permissible each 12 hours), in the following
conditions.
Altitude height 1000 meters and below.
Temperature lower limit -15°C, upper limit 40°C
2.Low noise
The power supply should be super low so that the doctors
can work in quiet, also the patients can have an undisturbed rest environment.
3.Necessarily protective equipments
The machine will automatically stops and give signals in
the following cases: low oil pressure, high temperature, over speed, start
failure. For auto start power generators with AMF function, ATS helps realize
auto start and auto stop. When the main fails, power generator can start within
5 seconds (adjustable). The power generator can start of itself consecutively
for three times. The switch from main load to generator load completes within
10 seconds and reaches rated power output in less than 12 seconds. When the
mains power gets back, the generators will automatically stop within 300
seconds (adjustable) after the machine cools.
4.Stable performance & high reliability
Average failure interval: not less than 2000 hours
Voltage regulation range: at 0% load between 95%-105% of
rated voltage.
Power Solution
Superb power generators, with PLC-5220 control module and
ATS, assures immediate power supply the same time the main is gone. The
generators adopt low noise design, and helps supply power in a quiet
environment. The engines are compliant with European and US emission standards.
The machine can be connected with computer with RS232 OR RS485/422 connector to
realize remote control.
Advantages
• Whole set product and turn-key solution help customer use
the machine easily without much technical knowledge. The machine is easy to use
and maintain.
• The control system has AMF function, which can auto start
or stop the machine. In emergency the machine will give an alarm and
stop.
• ATS for option. For small KVA machine, the ATS is
integral. Low noise.
• The noise level of the small KVA machine (30kva below) is
below 60dB(A)@7m.
• Stable performance. Average failure interval is not less
than 2000 hours.
• Compact size. Optional devices are provided for special
requirements for stable operation in some freezing cold areas and burning hot
areas.
• For bulk order, custom design and development is
provided.