Products
CT200E3/S3

CT200E3/S3

Basic information:
Engine: 6CTAA8.3-G2
Alternator: UCI274H
Controller: DSE6020
Dimension and Weight:
Silent:3600×1333×2040(3040kg)
Open: 2400×980×1460(1850kg)


0.00
0.00
  
Product Description

Basic information:
Engine: 6CTAA8.3-G2
Alternator: UCI274H
Controller: DSE6020
Dimension and Weight:
Silent:3600×1333×2040(3040kg)
Open: 2400×980×1460(1850kg)



Engine Specifications Alternator Specification
Model 6CTAA8.3-G2 Model UCI274H
Manufacturer CUMMINS Frequency and Speed 50Hz/1500rpm
Number of cylinders 6 Manufacturer STAMFORD
Cylinder arrangement In-line       Prime capacity(kVA) 200
Cycle Four stroke Exciter type Brushless
Induction system Turbocharged Insulation Class H
Compression ratio N/A Protection IP23
Bore x Stroke 114 x 135 mm Rated power factor 0.8
Displacement L 8.3 Stator winding Double layer concentric
Estimated total weight (dry) kg 702 Winding pitch two thirds
Rated power KW/HP 183/245 Winding leads 12
Lubrication oil capacity L 24 Maximum over speed 2250Rev/min
Coolant capacity L 45.3 THF (Wave Form IEC) 2%
Governer method Electronic TIF (Wave Form NEMA) 50
Starting system Electric Voltage regulation 1.00%
Exhaust System Lubrication system
Silence Type Industrial Total System Capacity 24litre
Exhaust gas flow (max) 485 litre Normal oil pressure 276-414kPa
Exhaust gas temperature (max) 545 Normal oil temperature ≤121
Engine Electrical System Fuel system
Battery charging alternator Type of injection model BYC pump
Ground (negative/positive) Negative 110% Fuel Consumption (prime) L/H 52.4
Starter motor rated voltage (DC) 24 V 100% Fuel Consumption (prime) L/H 45.8
Battery voltage 12 V 75% Fuel Consumption (prime) L/H 35
Volts (DC) 24 V 50% Fuel Consumption (prime) L/H 24.3
Cooling System
Coolant capacity (engine Only) L 12.3 Maximum coolant temperature 100
Thermostat operation range 82 - 95 Minimum Pressure Cap 69kPa
Minimum Top Tank Temperature(Prime) 100 Maximum Top Tank Temperature(Standby) 104

CT POWER Cummins series gensets have a wide power range from 22~1500KVA, which have open type, silent type, trailer type and container type which are widely used in industrial, commercial, backup, primary power source and outdoors project work and so on.